missing translation for 'onlineSavingsMsg'
Learn More

Spectrophotometry Holmium Oxide Solution UV and Visible Wavelength Standard 240 nm to 640 nm, Reagecon
BIOPHARMA

Product Code. 13502080 Shop All Reagecon Products
missing translation for 'changeView'
missing translation for 'orderingAttributeHoverText'
Quantity:
100 mL
missing translation for 'unitSize'
100mL
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Product Code. Quantity unitSize
13502080 100 mL 100mL
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 missing translation for 'options'
This item is not returnable. View return policy
Product Code. 13502080 missing translation for 'mfr' Reagecon missing translation for 'supplierNo' RSPEC00151

Please to purchase this item. Need a web account? Register with us today!

This item is not returnable. View return policy

Used for validation of the wavelength scale of a spectrophotometer in both the UV and visible regions.

  • Spectrophotometry Reference Standard, Spectrophotometry Reference Material.
  • Provides peak wavelengths between 240 nm and 640 nm that includes a spectral scan at various wavelengths including 0.1, 0.2, 0.5, 1.0 and 2.0 nm slit widths.
  • Used for validation of the wavelength scale of a spectrophotometer in both the UV and Visible regions.
  • This spectrophotometry standard is prepared gravimetrically on a weight/weight basis.
  • Both solute and solvent are weighed on a balance calibrated by Reagecon engineers using OIML traceable weights.
  • Reagecon holds ISO 17025 accreditation for calibration of laboratory balances (INAB Ref:265C).
  • The resulting Balance Certificate of Calibration is issued in accordance with the requirements of ISO/IEC 17025.
  • The certified values of each standard are verified using a high performance spectrophotometer calibrated with NIST traceable, ISO Guide 34 Certified Standards.

Specifications

Packaging Amber Glass Winchester Bottle
Quantity 100 mL
compliance-icons
Product Identifier
  • holmium oxide solution UV and visible wavelength standard 240nm tp 640nm
Signal Word
  • Danger
Hazard Category
  • Skin corrosion/irritation Category 1 B
  • Serious eye damage/eye irritation Category 1
Hazard Statement
  • H314-Causes severe skin burns and eye damage.
Precautionary Statement
  • P303+P361+P353-IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower.
  • P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P310-Immediately call a POISON CENTER/doctor/.
  • P321-Specific treatment (see on this label).
  • P405-Store locked up.
  • P501b-Dispose of contents/container in accordance with local/regional/national/international regulations.
Supplemental information
  • MIXTURE LIST-Contains : perchloric acid
Product Title
Select an issue

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.