missing translation for 'onlineSavingsMsg'
Learn More

BINDER™ Environmental Walk-in Chambers for Stability Testing and Storage
BIOPHARMA

Produktkode 17872755 Shop alle BINDER produkter
missing translation for 'orderingAttributeHoverText'
Dimensions (D x W x H) Interior:
2400 x 2300 x 2270 mm
2400 x 3400 x 2270 mm
2400 x 4700 x 2270 mm
Förpackningsstorlek
Each
Denne vare kan ikke returneres. Se returpolitik

Produktkode 17872755

missing translation for 'mfr': BINDER™ 98000013

Kun null tilbage
Tilføj til indkøbskurv
Tilføj til indkøbskurv
Denne vare kan ikke returneres. Se returpolitik

These walk-in-chambers offer a wide range of features and benefits to meet requirements in stability testing. Ideal test conditions are maintained in a wide range of temperatures, from 10°C to 50°C, with a relative humidity of 20% to 90% RH.

  • Relative humidity accuracy of ±2.5%
  • Temperature accuracy of ±1.5°C
  • Duct work for proper distribution of air
  • Highly insulated room panels with U value of only 0.21 W/m²K
  • LED lighting with motion detector
  • High quality room elements, made in Germany
  • Interior completely stainless steel
  • Exterior service accessibility
  • Room Elements: Galvanized sheet steel, polyester coated, white, similar to RAL 9010, interior surfaces in stainless steel
  • 4 inch/100 mm PU foam U value: 0.21 W/m²K
  • Floor: Floor overlay is chrome-nickel steel, pattern-rolled 5 WL
  • Surface load: 50,000 N/m²

Tekniske data

Chamber Material Stainless Steel
Lighting LED
Material Galvanized Steel
No. of Shelves 0
Plug Type EU, UK
Relative Humidity 20 to 90%
Temperature Range (Metric) 10°C to 50°C
Type Walk-in Chamber
Model WIC3-230V
Temperature Uniformity ±1.5 K at 40°C and 75% RH
Dimensions (D x W x H) Interior 2400 x 4700 x 2270 mm
Dimensions (L x W x H) 2600 x 4700 x 2470 mm
Weight (Metric) 1186 kg
Voltage 200/230 V
Wattage 2.7 kW
Amperage 11.5 A
Frequency 50 Hz
Vis mere Vis mindre
Korrektion af produktindhold

Dit input er vigtigt for os. Udfyld denne formular for at give feedback relateret til indholdet på dette produkt.

Produkttitel

Ved at klikke på Send, anerkender du, at du kan blive kontaktet af Fisher Scientific med hensyn til den feedback, du har givet i denne formular. Vi deler ikke dine oplysninger til andre formål. Alle angivne kontaktoplysninger skal også vedligeholdes i overensstemmelse med vores Privatlivspolitik.

Mange tak! Din feedback er blevet sendt. Hos Fisher Scientific arbejder vi altid på at forbedre vores indhold for dig. Vi sætter pris på din feedback.