Mettler Toledo™ Buffer Solutions: Standard pH
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Storage and refill solutions for pH electrodes
| Includes | Quality inspection certificate |
|---|---|
| Boiling Point | ∼100°C |
| Type | Buffer Solution |
| Water Soluble | Completely Miscible |
| Filling Solution Type | pH Buffer |
Mettler Toledo™ KCl 3M Electrode Filling Solution
Equipped with a special cap to facilitate easy filling of electrodes. Mettler Toledo™ KCl 3M Electrode Filling Solution is an electrolyte solution that enables optimum performance of pH and ion-selective electrodes. This bridge electrolyte contains no silver ions than can contaminate samples.
| pH Range | Neutral |
|---|---|
| For Use With (Equipment) | ARGENTHAL™ Reference System pH Electrodes, DX Series ISE Half Cells |
| Color | Colorless |
| Packaging | Bottle with Special Filling Cap |
| Concentration | 3 mol/L KCl |
| NIST Traceable | Yes |
METTLER TOLEDO™ InLab™ Expert pH Electrodes
A combination pH electrode with PEEK plastic shaft for chemical and mechanical durability, and a fixed cable. Designed for use in a variety of applications.
| Diameter (English) | 0.47 in. |
|---|---|
| Length (Metric) | 120 mm |
| pH Range | 0 to 14 |
| Diameter (Metric) | 12 mm |
| Membrane | U Glass |
| Filling Solution Type | Xerolyt Polymer |
| Material | PEEK |
| Temperature (Metric) Operating | 0°C to 100°C |
| Internal Reference | ARGENTHAL |
METTLER TOLEDO™ InLab™ Routine pH Electrodes
A combination pH electrode with an integrated temperature sensor and chemically resistant HA glass body. It is designed for general lab applications and ideal for use at high pH values (IP67 rated).
| Type | Combination Electrode |
|---|---|
| Temperature (Metric) Range | 0°C to 100°C |
| pH Range | 0 to 14 |
| Membrane | HA Glass |
| Material | Glass |
| Junction | Ceramic |
| Temperature (Metric) Operating | 0°C to 100°C |
Mettler Toledo™ NIST/DIN pH Buffer Solution Sachets
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Offers the highest possible pH precision. Mettler Toledo™ NIST/DIN pH Buffer Solution Sachets are specified to three decimal places and come with a printed certificate that guarantees traceability. Individual packets guarantee fresh solution for every calibration, as well as maximum ease of use.
| For Use With (Equipment) | pH Electrode |
|---|---|
| Quantity | 30 x 20 mL |
| For Use With (Application) | pH measurement, electrode calibration |
| NIST Traceable | Yes |
Fisherbrand™ accumet™ AE series Double Junction Gel pH Electrode
Fisherbrand™ accumet™ AE series pH electrodes support the accumet™ AE150 pH meter for routine pH measurements at a budget-friendly price.
Thermo Scientific™ Eutech™ ECFC7252101B pH electrode
Eutech™ offers a wide range of pH meters and electrodes that measure pH values in various educational, laboratory and industrial applications.
Thermo Scientific™ Orion™ ISE Ionic Strength Adjustors (ISA) and Special Reagents
Take more accurate and reproducible ISE measurements with Thermo Scientific™ Orion™ ISE Ionic Strength Adjustors (ISA) and Special Reagents.
| For Use With (Application) | Ionic strength adjustors used for analysis with ion selective electrodes and special reagents used with some ion selective electrodes |
|---|
Fisherbrand™ accumet™ AE Series 3-in-1 Single Junction Gel pH/ATC Electrode
Fisherbrand™ accumet™ AE series pH electrodes support the accumet AE150 pH meter for routine pH measurements a budget-friendly price
Thermo Scientific™ Orion™ Chloride Ion Selective Electrodes
Easily and reliably analyze free chloride ions in aqueous solutions. Provides quick, accurate and economical measurements.
| Type | Combination ISE |
|---|---|
| For Use With (Equipment) | Chloride electrodes can be used on any ISE meter with a BNC connection The electrodes can also be used on meters with a variety of inputs when an adapter cable is used. |
Fisherbrand™ accumet™ AE series single junction gel pH electrode
Fisher Scientific™ accumet™ AE series pH electrodes support the accumet™ AE150 pH meter for routine pH measurements a budget-friendly price
Thermo Scientific™ Orion™ Single Junction Refillable Epoxy Bodied pH/ATC Triode™
Accurately measure pH and temperature together in just one electrode, with a built-in temperature sensor.
| Diameter (English) Body | 0.47 in. |
|---|---|
| Length (Metric) | 120 mm |
| Temperature (English) Operating | 32°F to 194°F |
| For Use With (Equipment) | Orion pH Meter (field or plant-use) |
| pH Range | 0 to 14 |
| Diameter (Metric) Cap | 16 mm |
| Length (English) | 4.7 in. |
| Material | Epoxy |
| Junction | Glass Fiber |
| Diameter (Metric) Body | 12 mm |
| For Use With (Application) | ideal for field or plant use. |
| Temperature (Metric) Operating | 0°C to 90°C |
| Internal Reference | Ag/AgCl |
Thermo Scientific™ Orion™ Storage Sleeve and Base
Protect electrodes from breakage when not in use with the Thermo Scientific™ Orion™ Electrode Storage Sleeve and Base.
Thermo Scientific™ Eutech™ ECFC7252201B pH/Temperature Combination Electrode
Eutech™ offers a wide range of pH meters and electrodes that measure pH values in various educational, laboratory and industrial applications.
Mettler Toledo™ Economy Series pH and pH/ATC Combination Electrodes
Offer outstanding price/performance ratio. Mettler Toledo Economy Series pH and pH/ATC Combination Electrodes are cost-effective alternative for less-demanding requirements.
| Temperature (Metric) Range | 0°C to 100°C |
|---|---|
| Temperature (English) Operating | 0°F to 176°F |
| For Use With (Equipment) | pH meter |
| Length (English) Cable | 47 in. |
| Temperature (Metric) Operating | 0°C to 80°C |
| Connector Types | BNC |