UV-Vis Spectrophotometers
- (1)
- (6)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (7)
- (6)
- (3)
- (2)
- (1)
- (1)
- (12)
- (17)
- (1)
- (1)
- (33)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (60)
- (9)
- (2)
- (2)
- (1)
- (8)
- (1)
- (8)
- (9)
- (2)
- (2)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (8)
- (1)
- (1)
- (1)
- (1)
- (1)
- (32)
- (3)
- (2)
- (1)
- (1)
- (1)
- (6)
- (1)
- (3)
- (9)
- (3)
- (2)
- (1)
- (4)
- (20)
- (2)
- (4)
- (1)
- (11)
- (2)
- (24)
- (1)
- (2)
- (3)
- (2)
- (16)
- (2)
- (14)
- (42)
- (3)
Filtered Search Results
Jenway™ Model 7300 Visible Single Beam Spectrophotometer
Ideal for routine testing in clinical, veterinary, pharmaceutical and QC laboratories. Jenway™ Model 7300 Visible Single Beam Spectrophotometer uses icon-driven software and has improved navigation system for easy and intuitive usability.
Biochrom Biowave 3
The Biowave 3 offers all the capabilities of a research grade spectrophotometer with a robust design and a reasonable cost make it great for students.
| Shape | Round |
|---|---|
| Width (English) | 10 in. |
| Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
| Noise | ±0.005 peak to peak ±0.002 RMS |
| Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
| For Use With (Application) | UV/Vis Spectrophotometry |
| Light Source | Xenon Flash |
| Width (Metric) | 260 mm |
| Detector Type | Twin CMOS Array |
| For Use With (Equipment) | Microvolume Cuvettes |
| Voltage | 100/115/220/230 V |
| Stray Light | >0.5 %T 340 nm |
| Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
| Weight (Metric) | 3 kg |
| Height (English) | 3.9 in. |
| Height (Metric) | 100 mm |
| Beam Center Height | 15 mm |
| Depth (English) | 15.3 in. |
| Monochromator | Flat Grating |
| Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
| Wavelength Repeatability | ±1 nm |
| Spectral Bandwidth | 5 nm |
| Type | UV-Vis Spectrophotometer |
| Wavelength Accuracy | ±2 nm |
| Depth (Metric) | 390 mm |
| Weight (English) | 6.6 lb. |
| Wavelength Range | 190 to 1100 nm |
| Product Line | Biowave 3 |
| Display | Graphic LCD |
Thermo Scientific™ SPECTRONIC™ 200 Spectrophotometer
Thermo Scientific™ SPECTRONIC™ 200 is the standard for rugged, simple-to-use visible spectrophotometers for teaching and routine applications.
Jenway™ 72 Series Scanning Spectrophotometers Model 7200
The first scanning spectrophotometers in the Jenway range to leverage diode array technology to produce exceptionally fast results. Model 7200 covers a wavelength range of 335 to 800 nm with a spectral bandwidth of 7 nm.
Jenway™ Model 731001 Visible Single Beam Spectrophotometer
Ideal for routine testing in clinical, veterinary, pharmaceutical and QC laboratories.
Implen™ NanoPhotometer™ NP80 Nano-Volume and Cuvette UV-VIS Spectrophotometer
The Implen NanoPhotometer™ NP80 UV/Vis spectrophotometer for NanoVolume and cuvette applications. Quantify DNA, RNA, proteins and scan other samples within seconds.
| Connections | 2x USB A, USB B, Ethernet, WiFi |
|---|---|
| Operating Temperature | 37 °C ± 0.5 °C Cuvette |
| Beam Center Height | 8.5 mm |
| Processor | Linux based NPOS |
| Spectral Bandwidth | <1.8 nm |
| Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
| Absorbance Range | 0.02 to 330 A NanoVolume, 0 to 2.6 A Cuvette |
| Pathlength | 0.67 and 0.07 mm |
| For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
| Light Source | Xenon Flash |
| Measurement Time | 2.5 to 4.0 sec |
| Sample Volume (Metric) | 0.3 to 2 μL |
| Detector Type | 3648-element CCD Array |
| Dimensions (L x W x H) | 20 x 20 x 12 cm |
| Wavelength Accuracy | ± 0.75 nm |
| No. of Samples | 1 |
| System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
| Voltage | 90/250 V |
| Stray Light | < 0.5% @ 240 nm using NaI |
| Absorbance Accuracy | < 1.75% at 0.7 A at 280 nm of the reading |
| Wavelength Range | 200 to 900 nm |
| Measurement Range | 1 to 16,500 ng/μL |
| Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Lovibond™ Colorimeter Tablet Reagent: DPD No. 3
For use with MC500, MD600, SC450, MD100 colorimeters, SP600 spectrophotometer, Pool Control 9, AquaPRO3 Pool and AquaPRO6 Pool photometers and Scuba II Electronic Pool Tester.
Lovibond™ LC 100 Hand-Held Imaging Spectrophotometer
Creates conformance reports in either PDF or Excel formats that can easily be shared with PC or compatible printer
| Includes | Spectrophotometer, holder, sample cells, USB cord, carrying case |
|---|---|
| Measurement Time | 1.8 sec. |
| Display | TFT |
Lovibond™ Colorimeter Tablet Reagent: DPD No. 1
Use with MC500, MD600, SC450, MD100 colorimeters, SP600 spectrophotometer, Pool Control 9, AquaPRO3 Pool and AquaPRO6 Pool photometers and Scuba IIElectronic Pool Tester
Thermo Scientific™ Orion™ AquaMate Vis and UV-Vis Spectrophotometers
Optimized for your water analysis needs AquaMate 7100 Vis and AquaMate 8100 UV-Vis Spectrophotometers provide fast and reliable results
| Photometric Accuracy | ±0.002 A at 0.5 A, ±0.004 A at 1.0 A, ±0.008 A at 2.0 A |
|---|---|
| Connections | Single USB-A Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available |
| Height (Metric) | 19.5 cm |
| Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/240 V, 50/60 Hz |
| Warranty | 1 Year |
| Length (Metric) | 35.5 cm |
| Noise | (RMS at 500 nm 60 consecutive measurements) ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
| Wavelength Repeatability | < ±0.2 nm |
| For Use With (Application) | Water and Waste Water Analysis |
| Width (Metric) | 38.5 cm |
| Detector Type | Dual Silicon Photodiodes |
| Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
| Wavelength Accuracy | ±0.5 nm |
| Depth (Metric) | 35.5 cm |
| Compartments | Accessible from top, front or side Able to accommodate cells up to 100 mm cells Available accessory for test tubes up to 25 mm diameter and 150 mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
| Keypad | Glove- friendly touchscreen |
| Certifications/Compliance | CE / TUV |
| Optical Design | Double Beam |
| Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
| Interface | Glove friendly touch-screen |
| Weight (Metric) | 7.5 kg |
| Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
| Display | 7 in. High Definition Color Touchscreen, Fixed, 800 x 1280 pixels |
Eppendorf™ BioSpectrometer™ Fluorescence Reference Filter Set
The Eppendorf BioSpectrometer™ Fluorescence Reference Filter Set is designed for verifying photometric accuracy and wavelength systematic error (according to NIST Standards) and verifying fluorimetric precision (random error) and linearity.
Lovibond™ Colorimeter Fluoride Solution Reagent: SPADNS
For use with Fluoride Aqua Comparator Test Kit, MD600, MD100 Fluoride colorimeters, MD600 Multi-Parameter Colorimeters, Multidirect and Spectrodirect Spectrophotometer, XD7000
Lovibond™ Colorimeter Reagent Set: Ozone
For use with MC500, MD600 colorimeter and SP600 spectrophotometer.