Filtered Search Results
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C
Combines fine particle retention with good flow rate. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C are ideal for the collection of suspended solids in potable water, natural and industrial wastes.
| Thickness (Metric) | 260 μm |
|---|---|
| Flow Rate | 10.5 sec./100 mL |
| Particle Retention | 1.2 μm |
| Temperature (English) Max. | 932°F |
| Basis Weight | 53 g/m2 |
| Shape | Circle |
| Format | Disc |
| Description | GE’s Whatman filter paper Grade GF/C glass filters offer a good flow rate and loading capacity that support total suspended solids analysis. |
| Thickness (English) | 0.01 in. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/C |
| Material | Borosilicate Glass |
| Waterflow Rate | 105 mL/min |
Cytiva HyClone™ Dulbecco's Phosphate Buffered Saline, Solution
Buffer cell culture with PBS in solution.
| Regulatory Status | RUO |
|---|---|
| Content And Storage | 15° to 30°C |
| Sterilization Method | 0.1 μm Sterile-filtered |
| Product Type | Dulbecco's Phosphate Buffered Saline |
| Form | Liquid |
| Endotoxin Level | ≤0.025EU/mL |
| pH | 7 to 7.6 |
| Shelf Life | 24 Months |
| Certifications/Compliance | Manufactured under cGMP and ISO 9001 certified facilities |
| For Use With (Application) | Serves as an irrigating, transporting or diluting fluid while maintaining cell tonicity and viability for a limited period of time |
| Osmolality | 276±10mOsm/kg H2O |
| Sterility | Sterile |
Cytiva Whatman™ Lens Cleaning Tissue
Provides scratch-free cleaning solutions. Whatman™ Lens Cleaning Tissue safely removes surface moisture and grease.
| Description | Won't damage lenses or optical surfaces, leaves no fibers |
|---|---|
| Product Type | Lens Wipe |
| For Use With (Application) | Safe removal of surface moisture and grease. |
Cytiva Amersham™ ECL Select™ Western Blotting Detection Reagent
Use as a high sensitivity reagent for chemiluminescent Western blotting detection. Cytiva Life Sciences™ Amersham™ ECL Select™ Western Blotting Detection Reagent provides highly intense signal output, for detection of medium to very low protein levels.
Cytiva Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles
Served as the basis filter for EPA standard for the toxicity characteristic leaching procedure. Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles offers an extremely high loading capacity and flow rate.
| Particle Retention | 0.7 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | Whatman Grade GF/F filter from Cytiva's business is manufactured from pure borosilicate glass. GF/F offers very fine particle retention and good loading capacity and flow rate. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/F |
| Material | Borosilicate Glass |
| For Use With (Application) | Recommended for DNA binding and purification.Very effective in filtering finely precipitated proteins.Can be used in conjunction with GF/D as a prefilter for the successful clarification of extremely ‘difficult’ biochemical solutions and fluids and nucl |
| Thickness (Metric) | 420 μm |
| Flow Rate | 19 sec./100mL/in.2 |
| Type | Filter for TCLP Test Use |
| Format | Disc |
| Thickness (English) | 0.016 in. |
| Autoclavable | Autoclavable |
| Waterflow Rate | 41 mL/min |
Cytiva Amersham™ ECL™ Prime Western Blotting Detection Reagent
Enables the use of highly diluted primary and secondary antibodies without reducing sensitivity. Cytiva Lifescience™ Amersham™ ECL™ Prime Western Blotting Detection Reagent produces high signal intensity and sensitivity.
| Sensitivity | ∼1 pg |
|---|---|
| Product Type | ECL Western Blot Detection Reagent |
| For Use With (Application) | Sensitive Quantitative or Confirmatory Western Blot |
Cytiva Percoll™ Centrifugation Media
For separation of cells, subcellular particles, and larger viruses (down to approx. 70S) under gentle conditions that preserve viability and morphological integrity. Cytiva™ Percoll™ Centrifugation Media Percoll is composed of colloidal silica coated with polyvinylpyrrolidone (PVP).
| Viscosity | 15cP |
|---|---|
| Content And Storage | 4–30°C |
| Form | Liquid |
| Product Type | Centrifugation Media |
| Color | Colorless to Slightly Yellow |
| pH | 8.5 to 9.5 |
| Shelf Life | 5 years |
| For Use With (Application) | Cell Isolation |
| Density | 1.135 g/mL |
| Osmolality | < 25 mOsm/kg |
Cytiva Whatman™ HEPA-Vent Filter
Strengthened glass filter media by dual lamination with a tough polyester monofilament. Whatman™ HEPA-Vent Filters are ideal for air and gas filtration applications where high retention, dirt-holding capacity and flow rates are required.
Cytiva Pharmalyte™ Carrier Ampholytes
Use in Isoelectric focusing. Cytiva Pharmalyte™ Carrier Ampholytes prepared by the co-polymerization of glycine, glycylglycine, amines, and epichlorohydrin, are available in five broad-range and four narrow-range pH intervals.
| Form | Liquid |
|---|---|
| Product Type | Pharmalyte carrier Ampholyte |
| For Use With (Equipment) | PhastSystem Automated Electrophoresis Unit |
| Formulation | Co-polymerization of Glycine, Glycylglycine, Amines and Epichlorohydrin |
| Color | Colorless to Light Yellow |
| Quantity | 25mL |
| Storage Requirements | 2° to 8°C |
| For Use With (Application) | IEF |
Cytiva HisTrap™ FF Columns: 16 x 25mm
Use for optimized purification of histidine-tagged proteins directly from homogenized, unclarified cells by immobilized metal ion affinity chromatography (IMAC). Cytiva Life Sciences™ HisTrap™ FF Columns: 16 x 25mm is a ready-to-use column, prepacked with precharged Ni Sepharose™ 6 Fast Flow.
| Flow Rate | <20 mL/min. |
|---|---|
| Type | Pre-packed Column |
| Content And Storage | 4°C to 30°C, 20% Ethanol |
| Diameter (English) Inner | 0.6 in. |
| Description | HisTrap FF is a ready-to-use column, prepacked with precharged Ni Sepharose 6 Fast Flow for preparative purification of histidine-tagged recombinant proteins by immobilized metal ion affinity chromatography (IMAC). |
| Max. Operating Pressure | 5 bar (0.5 MPa, 70 psi) |
| pH Range | 3 to 12 |
| Diameter (Metric) Inner | 16 mm |
| Material | Polypropylene |
| Support Type | 6% Cross-linked Agarose |
Cytiva Whatman™ Qualitative Grade Plain Circles and Sheets - Grade 3
Used for high precipitate capacity and increased wet strength. Whatman™ Qualitative Grade Plain Circles and Sheets - Grade 3 provide double the thickness of Whatman Grade 1.
| Thickness (Metric) | 390 μm |
|---|---|
| Grade | Grade 3 |
| Material | Cellulose |
| For Use With (Application) | A standard grade filter used in qualitative analytical techniques to determine and identify materials. For use in büchner funnels. |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
| Temperature (Metric) Max | 500°C |
| Quantity | 100 Pieces |
| Grade | Grade GF/A |
| Material | Borosilicate Glass |
| For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
| Thickness (Metric) | 260 μm |
| Flow Rate | 13 sec./100mL |
| Type | Fine Retention Filter |
| Format | Disc |
| Thickness (English) | 0.01 in. |
| Waterflow Rate | 143 mL/min |
Cytiva Whatman™ Qualitative Filter Paper: Grade 4 Circles
Filters and retains coarse particles for monitoring air pollution. Whatman™ Qualitative Filter Paper: Grade 4 Circles are used when high flow rates in air pollution monitoring are required and the collection of fine particles is not critical.
| Thickness (Metric) | 210 μm |
|---|---|
| Pore Size | 20 to 25 μm |
| Flow Rate | Fast |
| Particle Retention | 25 μm |
| Format | Disc |
| Grade | Grade 4 |
| Material | Cellulose |
| Porosity | Medium |
| Filtration Speed | 37 sec. |
Cytiva Whatman™ Mini-UniPrep™ Syringeless Filters with Preslit Septa
Processes sample loads in one-third the time. Whatman™ Mini-UniPrep™ Syringeless Filters with Preslit Septa provide a faster and easier way to remove particulates from samples being prepared for HPLC and UHPLC analysis.
| For Use With (Application) | Routine HPLC/UHPLC analysis; Composite assays; Content uniformity; Protein precipitation; Solubility testing; Dissolution testing; Sample filtration; Standard robotics on HPLC instruments with sensitive needles, allowing for higher throughput; Light sen |
|---|