missing translation for 'onlineSavingsMsg'
Learn More
Learn More
Description
- Feature membrane keypads and clear digital displays for ease of programming
- Timed or continuous runs from 1 min. to 500 hrs., with end-of-run alarm
- Automatic parameter limit crossover prevents overheating, protects experiments and equipment
- Two pairs of power outlets permit duplicate parallel runs
- Automatic recovery after power failure
Four available modes (depending on model)
- Constant current mode is recommended for blotting to prevent overheating
- Constant voltage mode is recommended for other applications, such as nucleic acid submarine and mini-vertical gel electrophoresis
- Constant power mode is designed for constant temperature runs without a circulating cooler
- Linear voltage ramp mode brings proteins to focused equilibrium in IPG strips quickly without danger of overheating
EPS 3501
- Primarily designed for manual DNA sequencing and IEF applications
- Also suitable for many electrophoresis and blotting applications
- Constant voltage, constant current, or constant power modes
- Stores and recalls three protocols
- Primarily designed for 2-D electrophoresis and IEF using ImmobilineTM, but also suitable for many other electrophoresis applications
- For high-voltage applications requiring advanced programming
- Constant voltage, constant current, constant power, and linear voltage ramp modes
- Stores and recalls 9 protocols, each with 9 phases and phase-end alarms
- Programmed automatic shut-off or phase end based on time, volt-hour/milliampere-hour
Order Info
D x W x H: 12 1/4 x 9 3/4 x 3 3/4 in. (31.0 x 25 x 9.5cm)
Specifications
Specifications
| Certifications/Compliance | EN61010-1, CE 89/336/EEC (EMC directive), CE 73/23/EEC (LV directive) |
| For Use With (Equipment) | Immobiline Dry strip, IPG, Electrophoresis, Basic Blotting |
| Timer | 1 min. to 500 hr. |
| Type | EPS 3501 XL Power Supply |
| Display | Digital |
| Humidity Range | 0 to 0.95% |
| Max. Pressure | 106 kPa |
| Opening Dimensions (Metric) | 0.2 cm |
| Temperature (English) Operating | 39.2°F to 104°F |
| Temperature (Metric) Operating | 4°C to 40°C |
| Show More |