Filtered Search Results
Mettler Toledo™ FiveEasy™ F20 pH/mV Meters
Compact, benchtop meter provides high quality pH/mV measurements with simple click of a button
| Accuracy (mV) | ±1 |
|---|---|
| Memory | Current calibration |
| Resolution (pH) | 0.01 |
| Range (pH) | 0 to 14 |
| Calibration | Linear |
| Accuracy (pH) | ±0.01 |
| Temperature Compensation | ATC and MTC |
| Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
| Display Type | LCD |
| Voltage | 120/240 V |
| Model | F20 |
| Resolution (mV) | 1mV |
| Frequency | 50/60 Hz |
| Temperature Range (English) | 32°F to 212°F |
| Weight (English) | 1.4 lb. |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | 0°C to 100°C |
| Range (mV) | 2000 to 2000 |
| Inputs | BNC, Cinch, NTC 30kiloOhm sensors |
| Accuracy (Temperature) | 0.5°C |
| Weight (Metric) | 0.63 kg |
Fisherbrand™ accumet™ FE150 Benchtop pH Meter
Provides the essential functions needed for routine pH measurements without complicated features and processes at a budget-friendly price.
| Accuracy (mV) | ±0.2 ±199.9 ±2 Beyond ±200 |
|---|---|
| Electrical Requirements | AC/DC 9 V Adapter (110/220 VAC, 50/60 Hz) |
| Memory | 100 Data Sets |
| Resolution (mV) | 0.1 mV (±199.9 mV); 1 mV Beyond ±200 mV |
| Outputs | Recorder (±2000 mV) |
| Temperature Probe Calibration | Offset in 0.1°C Increments; Offset Range: ±5°C |
| Resolution (Temperature) | 0.1°C |
| Range (pH) | 0 to 14 |
| Temperature Range (Metric) | 0°C to 100°C |
| Range (mV) | ±1999 mV |
| Inputs | BNC, 2.5 mm Phono Plug, Reference Pin Tip, Ground |
Fisherbrand™ accumet™ AET15 pH Tester
Large display screen - dual display LCD for enhanced readability, provides comprehensive meter information
Eutech Expert pH Pocket Tester
Perform on-the-go, fuss-free measurements for applications such as water treatment, environmental monitoring, education, hydroponics, agriculture, aquaculture, food & beverage and many more!
Thermo Scientific™ Elite pH Pocket Testers and Replacement Sensors
Flexible on-the-go pH and temperature testing using durable Elite pocket testers with replaceable sensors for a variety of applications including environmental monitoring, pools, spas and more!
Thermo Scientific™ Elite PCTS pH / Conductivity / TDS / Salinity Pocket Testers and Replacement Sensors
Flexible on-the-go pH, conductivity, TDS, salinity and temperature testing using durable Elite PCTS pocket testers for a variety of applications including agriculture, aquaculture, hydroponics and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Resolution (pH) | 0.01 |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | pH,Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| Range (pH) | -1.00 to 15.00 |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Accuracy (pH) | ±0.02 |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Calibration Points (pH) | 1 to 3 |
| Calibration Modes | pH, conductivity, TDS, salinity, temperature |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Eutech™ EcoTestr pH Meter
Eutech™ offers a wide range of pH meters and electrodes that measure pH values in various educational, laboratory and industrial applications.
| Battery Life | 250 hr. |
|---|---|
| IP Rating | IP67 |
| Resolution (pH) | 0.1 |
| Measurement Modes | pH |
| Range (pH) | 0 to 14 |
| Battery Type | A76/LR44 Alkaline |
| Accuracy (pH) | ±0.1 |
Fisherbrand™ accumet™ Basic AB315 Benchtop Laboratory pH/mV Meter
Ideal for daily pH testing of your routine laboratory samples, the accumet™ Basic AB315 Benchtop Meter provides essential functions needed for common pH measurements without complicated functions, all at a budget-friendly price.
| Memory | Non-volatile |
|---|---|
| Resolution (pH) | 0.01, 0.1 |
| Measurement Modes | pH with mV and Temperature,Relative mV with mV and Temperature |
| Range (pH) | -2 to 18 |
| Channels | 1 |
| Accuracy (pH) | ±0.01 |
| Temperature Compensation | Automatic, Manual |
| Data Management Details | Printed or CSV Format |
| Display Type | 5 in. LCD |
| Voltage | 100/240 V |
| Resolution (mV) | 1 mV, 0.1 RmV |
| Data Points | 500 |
| Inputs | BNC, ATC |
| Accuracy (Temperature) | ±0.3°C (±0.5°F) |
| Accuracy (mV) | ±0.2 or ±0.05%, Whichever is Greater |
| Stability | Indicator Icons |
| Warranty | 3 Years |
| AC Adapter | Universal Power Adapter |
| Log Function Type | Automatic, Manual |
| Calibration | pH, Relative mV, Temperature |
| Calibration Points | 1 to 5 (pH), 1 (Relative mV), 1 (Temperature) |
| IP Rating | IP54 |
| Model | AB315 |
| Outputs | Port for Computer or Printer |
| Frequency | 50/60 Hz |
| Range (Relative mV) | ±2000 mV |
| Backlight Option | Yes |
| Temperature Range (English) | 23°F to 221°F |
| Calibration Points (pH) | USA: 2, 4.01, 7, 10.01, 12; NIST: 1.68, 4.01, 6.87, 9.18, 12.46; DIN: 1.09, 3.06, 4.65, 6.79, 9.23, 12.75; FSCI: 1, 3, 6, 8, 10, 13 |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature Range (Metric) | -5°C to +105°C |
| Range (mV) | ±2000 mV |
Thermo Scientific™ Orion™ Pro Star PH211 pH/ORP Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PH211 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Memory | Non-volatile |
|---|---|
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH with mV and Temperature,ORP with mV and Temperature |
| Range (pH) | -2 to 20 |
| Channels | 1 |
| Accuracy (pH) | ±0.002 pH |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Data Points | 10,000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Inputs | BNC for pH or ORP, 8-pin MiniDIN for ATC, pin-tip for reference |
| Accuracy (Temperature) | ±0.3°C, ±0.5°F |
| Weight (Metric) | 1.00 kg |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Isopotential Point | 7.000 pH |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Calibration | pH, ORP, Temperature |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 2 (Temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| IP Rating | IP54 |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Model | PH211 |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Range (Relative mV) | -2000 to 2000 mV |
| Backlight Option | Yes |
| Temperature Range (English) | -22°F to +266°F |
| Calibration Points (pH) | 1 to 5 points |
| Weight (English) | 2.20 lbs. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Temperature Range (Metric) | -30°C to +130°C |
| Range (mV) | -2000 to 2000 mV |
| Methods | 10 |
| Range (ORP) | -2000 to 2000 mV |
Thermo Scientific™ Eutech™ ECTestr11+ Multi Range Conductivity Tester
Get quick and accurate conductivity measurements in the field, laboratories, and schools.
Mettler Toledo™ FiveEasy™ Plus FP20 pH/mV Meters
Compact, benchtop meter provides high quality pH/mV measurements with simple click of a button.
| Accuracy (mV) | ±1 |
|---|---|
| Memory | 200 measurements, current calibration |
| Resolution (pH) | 0.01, 0.1 |
| Range (pH) | -2 to 16 |
| Calibration | Linear/Segmented |
| Accuracy (pH) | ±0.01 |
| Temperature Compensation | ATC and MTC |
| Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
| Data Management Details | RS232, USB |
| Display Type | LCD |
| Voltage | 120/240 V |
| Model | FP20 |
| Resolution (mV) | 1mV |
| Frequency | 50/60 Hz |
| Temperature Range (English) | 23°F to 221°F |
| Weight (English) | 1.4 lb. |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | -5°C to +105°C |
| Range (mV) | 2000 to 2000 |
| Inputs | BNC, Cinch, NTC 30kiloOhm sensors |
| Accuracy (Temperature) | 0.3°C |
| Weight (Metric) | 0.63 kg |
Thermo Scientific™ Orion Lab Star PH111 Bench pH Meters
Orion Lab Star PH111 benchtop pH meters measure pH or ORP with mV and temperature, feature a large backlit display for easy viewability, and offer small footprint to save bench space. The Orion Lab Star pH meter is ideal for simplified, budget-friendly lab testing and data recording.
| Memory | Non-volatile |
|---|---|
| Resolution (pH) | 0.001, 0.01, 0.1 |
| Measurement Modes | pH with mV and Temperature,ORP with mV and Temperature |
| Range (pH) | -2 to 18 |
| Data Management Details | Transfer single or all data points to printer or computer |
| Display Type | LCD, 5 in. Backlit |
| Resolution (mV) | 0.1 mV |
| Data Points | 500 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Inputs | BNC for pH or ORP, 8-pin MiniDIN for ATC |
| Accuracy (Temperature) | ±0.3°C/±0.5°F |
| Weight (Metric) | 700 grams |
| Accuracy (mV) | ±0.2 or ±0.05%, whichever is greater |
| Warranty | 3 year meter warranty |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Calibration | pH, ORP and temperature |
| Calibration Points | 1 (ORP) |
| Alarm Output | Calibration reminder alarm |
| IP Rating | IP54 |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Outputs | Computer or printer (STARA-106) |
| Backlight Option | Yes |
| Temperature Range (English) | 23.0°F to 221.0°F |
| Calibration Points (pH) | 1 to 5 points |
| Weight (English) | 1.54 lb. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Range (mV) | ±2000.0 |
| Range (ORP) | ±2000.0 mV with ±250 mV offset |
Thermo Scientific™ Orion Star™ A121 Portable pH Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Take simple pH and temperature measurements with our portable pH meter with easy operation for basic field testing.
| Memory | Non-volatile memory preserves log and settings |
|---|---|
| Resolution (pH) | 0.01, 0.1 |
| Languages | English |
| Measurement Modes | pH,mV,Relative mV with Temperature |
| Range (pH) | -2 to 16 |
| Channels | 1 |
| Accuracy (pH) | ±0.01 |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Battery Life | 2000 hr. |
| Data Management Details | Internal Data Point Memory |
| Display Type | LCD |
| Resolution (mV) | 0.1mV |
| Data Points | 50 |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Inputs | BNC (pH or ORP electrode), 8 pin MiniDIN (ATC temperature probe) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 0.5 kg |
| Accuracy (mV) | ±0.2 or ±0.05%, whichever is greater |
| Stability | Smart Stability and Smart Averaging |
| Warranty | 3 Year Meter Warranty |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.00pH |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Log Function Type | Automatic with Auto-Read Measure Mode, Manual with Continuous Measure Mode |
| Calibration | pH, relative mV (RmV) and temperature |
| Battery Type | 4 x AA |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Calibration Points | 1 to 3 |
| Dimensions (L x W x H) | 24 cm x 10 cm x 6.5 cm (9.5 in. x 3.9 in. x 2.6 in.) |
| IP Rating | IP67 |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Simple with highlighted measure key, scroll and shortcut keys |
| Model | Orion Star A121 Portable pH/mV/RmV/Temperature Meter |
| Outputs | None |
| Range (Relative mV) | ±1999.9mV |
| Temperature Range (English) | 22.0°F to 221.0°F |
| Weight (English) | 2 lb. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5°C to +105°C |
| Range (mV) | ±1600.0 |
Thermo Scientific™ Orion Star™ A329 pH/ISE/Conductivity/Dissolved Oxygen Portable Multiparameter Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Accurately measure pH, ion concentration, conductivity, dissolved oxygen and temperature with our pH/ISE/conductivity/RDO/DO portable meter.
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
|---|---|
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
| Pressure Range | 400 to 850mmHg |
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Resolution (pH) | 0.1/0.01/0.001 |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
| Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 5 |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0 % saturation |
| Battery Type | 4 AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (RDO) | 0.00 to 50.00mg/L |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Percent Saturation Range (RDO) | 0.0 to 500.0 % saturation |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
| Range (Polarographic DO) | 0.00 to 90.00mg/L |
| Range (mV) | ±2000.0 mV |
| Accuracy (Barometer) | ±6mmHg |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Pressure Resolution | 1mmHg |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Channels | 3 |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Resolution (RDO) | 0.01, 0.1mg/L |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Percent Saturation Resolution (RDO) | 0.1, 1 % saturation |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature) |
| Weight (Metric) | 0.5 kg |
| Calibration Points (Conductivity) | Up to 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH |
| Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Model | Orion Star A329 pH/ISE/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/RDO Optical/Dissolved Oxygen/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L |
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Cup-sensor Pocket Testers and Replacement Sensors
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS cup-sensor pocket testers for a variety of applications including agriculture, aquariums and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |