| Memory | Non-volatile |
|---|---|
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH with mV and Temperature,ORP with mV and Temperature |
| Range (pH) | -2 to 20 |
| Channels | 1 |
| Accuracy (pH) | ±0.002 pH |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Data Points | 10,000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Inputs | BNC for pH or ORP, 8-pin MiniDIN for ATC, pin-tip for reference |
| Accuracy (Temperature) | ±0.3°C, ±0.5°F |
| Weight (Metric) | 1.00 kg |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Isopotential Point | 7.000 pH |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Calibration | pH, ORP, Temperature |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 2 (Temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| IP Rating | IP54 |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Model | PH211 |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Range (Relative mV) | -2000 to 2000 mV |
| Backlight Option | Yes |
| Temperature Range (English) | -22°F to +266°F |
| Calibration Points (pH) | 1 to 5 points |
| Weight (English) | 2.20 lbs. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Temperature Range (Metric) | -30°C to +130°C |
| Range (mV) | -2000 to 2000 mV |
| Methods | 10 |
| Range (ORP) | -2000 to 2000 mV |
Thermo Scientific™ Orion™ Pro Star PI214 pH/ion Bench Meter
Designed to provide accurate and reliable pH, ORP, ion concentration and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PI214 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Temperature (Metric) Range | -30.0°C to +130.0°C |
|---|---|
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH with mV and Temperature,ORP with mV and Temperature,Ion Concentration (ISE) with Temperature |
| Range (pH) | -2 to 20 |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Channels | 1 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Data Points | 10,000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Inputs | BNC for pH, ORP or ion selective electrode (ISE), 8-pin MiniDIN for ATC, pin-tip for reference |
| Accuracy (Temperature) | ±0.3°C, ±0.5°F |
| Weight (Metric) | 1.00 kg |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Calibration Points (ISE) | Up to 5 |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Calibration | pH, ORP, Ion Concentration, Temperature |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Model | PI214 |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Weight (English) | 2.20 lbs. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Range (mV) | -2000 to 2000 mV |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 |
Thermo Scientific™ Orion™ Pro Star PC215 pH/ion and Conductivity Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PC215 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Range (Resistivity) | 1.0 Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Range (mV) | -2000 to 2000 mV |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Accuracy (Conductivity) | ±0.5% reading |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Calibration Points (Conductivity) | 1 to 5 points |
| Resolution (Resistivity) | 0.1 Ω minimum, auto-ranging |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ Pro Star PI217 Dual Channel pH/Ion Bench Meter
Designed to provide accurate and reliable pH, ORP, ion concentration and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PI217 dual channel bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Temperature (Metric) Range | -30.0°C to +130.0°C |
|---|---|
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH,ORP with mV and Temperature,Ion Concentration (ISE) with Temperature |
| Range (pH) | -2 to 20 |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Data Points | 10,000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference |
| Accuracy (Temperature) | ±0.3°C, ±0.5°F |
| Weight (Metric) | 1.00 kg |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Calibration Points (ISE) | Up to 5 |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Calibration | pH, ORP, Ion Concentration, Temperature |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Model | PI217 |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Weight (English) | 2.20 lbs. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Range (mV) | -2000 to 2000 mV |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
Thermo Scientific™ Orion™ Pro Star DO213 Dissolved Oxygen Bench Meter
Designed to provide accurate and reliable dissolved oxygen, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star DO213 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Temperature (Metric) Range | -30.0°C to +130.0°C |
|---|---|
| Resolution (Polarographic DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Pressure Range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Memory | Non-volatile |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | Dissolved Oxygen (mg/L with Temperature and Barometric Pressure),Dissolved Oxygen (ppm with Temperature and Barometric Pressure),Dissolved Oxygen (% Saturation with Temperature and Barometric Pressure) |
| Channels | 1 |
| Barometric Pressure Correction | Yes, automatic with built-in barometer or manual |
| Resolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
| Resolution (DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Data Points | 10,000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Probe Type | Polarographic or optical DO electrode |
| Inputs | 9-pin MiniDIN for dissolved oxygen with ATC |
| Accuracy (Temperature) | ±0.3°C, ±0.5°F |
| Weight (Metric) | 1.00 kg |
| Salinity Factor | 0.0 to 50.0 ppt |
| Accuracy (DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Warranty | 2 year meter warranty |
| Accuracy (Polarographic DO) | ±2% saturation; ±0.02 mg/L or ppm |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Range (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Percent Saturation Range (RDO) | 0.0 to 600.0% saturation |
| IP Rating | IP54 |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Keypad | Capacitive touchscreen user interface |
| Model | DO213 |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Backlight Option | Yes |
| Weight (English) | 2.20 lbs. |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Range (Polarographic DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Accuracy (Barometer) | ±6.0 mmHg; ±0.008 bar |
| Range (DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Methods | 10 |
| Accuracy (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
Thermo Scientific™ Orion™ Pro Star MP218 pH/ion, Conductivity and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion, conductivity, TDS, salinity, resistivity, DO, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star MP218 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Resolution (Polarographic DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Pressure Range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Range (Resistivity) | 1.0Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH,ORP,mV,Ion Concentration (ISE),Conductivity,Dissolved Oxygen (mg/L),Temperature,Barometric Pressure |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Barometric Pressure Correction | Yes, automatic with built-in barometer or manual |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Probe Type | Polarographic or optical DO electrode |
| Salinity Factor | 0.0 to 50.0 ppt; automatic with conductivity measurement or manual entry |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
| Range (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Percent Saturation Range (RDO) | 0.0 to 600.0% saturation |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
| Range (Polarographic DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Range (mV) | -2000 to 2000 mV |
| Accuracy (Barometer) | ±6.0 mmHg; ±0.008 bar |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (30 total) |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Channels | 3 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Resolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
| Accuracy (Conductivity) | ±0.5% reading |
| Resolution (DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC; Channel 3: 9-pin MiniDIN for dissolved oxygen with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Calibration Points (Conductivity) | 1 to 5 points |
| Accuracy (DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Resolution (Resistivity) | 0.1 Ωminimum, auto-ranging |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Polarographic DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, DO, Barometric Pressure, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Range (DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
Thermo Scientific™ Orion™ Pro Star EC212 Conductivity Bench Meter with Stand
Designed to provide accurate and reliable conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star EC212 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Range (Resistivity) | 1.0 Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Measurement Modes | Conductivity with Temperature,TDS with Temperature,Salinity with Temperature,Resistivity with Temperature |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Channels | 1 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Accuracy (Conductivity) | ±0.5% reading |
| Data Points | 10,000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Inputs | 8-pin MiniDIN for conductivity with ATC |
| Accuracy (Temperature) | ±0.3°C, ±0.5 °F |
| Weight (Metric) | 1 kg |
| Calibration Points (Conductivity) | 1 to 5 points |
| Warranty | 2 year meter warranty |
| Resolution (Resistivity) | 0.1 Ω minimum, auto-ranging |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | Conductivity, TDS, Salinity, Temperature |
| Calibration Points | 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| IP Rating | IP54 |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Model | EC212 |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Backlight Option | Yes |
| Temperature Range (English) | -22°F to +266°F |
| Weight (English) | 2.20 lbs. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Temperature Range (Metric) | -30°C to +130°C |
| Methods | 10 |
Thermo Scientific™ Orion™ Pro Star PD216 pH/ion and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion concentration, dissolved oxygen, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PD216 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Resolution (Polarographic DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
|---|---|
| Pressure Range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH,ORP,mV,Ion Concentration (ISE),Dissolved Oxygen (mg/L),Dissolved Oxygen (% Saturation),Temperature,Barometric Pressure |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Barometric Pressure Correction | Yes, automatic with built-in barometer or manual |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Probe Type | Polarographic or optical DO electrode |
| Salinity Factor | 0.0 to 50.0 ppt |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
| Range (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Percent Saturation Range (RDO) | 0.0 to 600.0% saturation |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
| Range (Polarographic DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Range (mV) | -2000 to 2000 mV |
| Accuracy (Barometer) | ±6.0 mmHg; ±0.008 bar |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
| Range (pH) | -2 to 20 |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Resolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
| Resolution (DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 9-pin MiniDIN for dissolved oxygen with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Accuracy (DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Polarographic DO) | ±2% saturation; ±0.02 mg/L or ppm |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Calibration | pH, ORP, Ion Concentration, DO, Barometric Pressure, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Range (DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±2% saturation; ±0.02 mg/L or ppm |