Eppendorf™ 5810 Centrifuges without Rotor
Microprocessor control ensures ease of use and reproducible results
Brand: Eppendorf™ 5810000017
Description
Available in two different sizes: the 5804 (and the refrigerated model 5804 R) can accommodate up to 400mL in the swing-bucket rotor while the 5810 (and the refrigerated model 5810 R) offer a capacity of 1, 600mL, also in the swing-bucket rotor. Low loading height, makes both centrifuges easy to load, unload and clean. Low noise levels ensure a pleasant working environment, and the motorised lid latch allows the lid to be closed easily, with very little force. The control panel is easy to follow: 34 programs can be stored and 10 startup and braking ramps are available for sensitive samples. A wide variety of test tubes may be used. Stand-by cooling and a 'Fast temperature' function allow sensitive samples to be cooled rapidly and reliably, even at maximum speed.- 4 x 400mL rectangular buckets for high capacity
- Ideal for medical and biotechnology laboratories: flexible adapters enable high sample throughput
- Rotor buckets, caps and adapters are autoclavable (121°C, 20min)
- Swing-bucket rotor A-4-81 can be upgraded with 4 MTP/Flex buckets to the MTP rotor A-4-81-MTP
- For up to 16 microtitre plates or 12 culture plates or 4 deep well plates and all plate stacks of the Perfectprep™ plasmid kit
- All in one rotor cross for 4 x 250mL rectangular buckets and 4 MTP buckets
- Flexible adapters for a wide range of tubes
- Swing-bucket rotor with rectangular buckets: maximum rotational speed: 4, 000rpm (max. RCF: 3, 150 x g)
- Swing-bucket rotor A-4-62 can be upgraded with 4 MTP buckets to the MTP rotor A-4-62-MTP
- For up to 16 microtitre plates, 12 culture plates or 4 deep well plates
- Swing-bucket rotor with MTP buckets: maximum rotational speed: 4, 000rpm (max. RCF: 2, 750 x g)
- Different combinations of stacked plates can be centrifuged
- Commercial nucleic acid purification kits up to a maximum height of 85mm can be used
- Simultaneous processing of up to 192 samples
- Maximum rotational speed: 3, 700rpm (max. RCF: 2, 250 x g)
- Rotors and buckets are autoclavable (121°C, 20min)
- 4 x 100mL rectangular buckets for high capacity
- Flexible adapters for a wide range of tubes
- Maximum rotational speed: 5, 000rpm (max. RCF: 4, 500 x g)
- Caps for aerosol-tight centrifugation
- Rotor buckets, caps and adapters are autoclavable (121°C, 20min)
- Also available with four buckets for conical 50mL tubes
- Horizontal centrifugation at high relative centrifugal force
- Particularly suitable for low sample quantities
- For pellet formation at bottom of the tube
- At maximum speed of 14, 000rpm (max. RCF: 16, 400 x g) a temperature of 4°C is maintained in the 5804 R and 5810 R
- Six boreholes for different tubes (max. tube size: 85mL)
- Maximum rotational speed: 11,000rpm (max. RCF: 15, 550 x g)
- When used in centrifuge 5810 R: maximum rotational speed: 12, 000rpm (max. RCF: 18, 500 x g)
- Conical tubes such as 15mL and 50mL: Falcon™ tubes can be centrifuged with adapters in the fixed angle rotor
- Rotors, caps and adapters are autoclavable (121°C, 20min)
- 30 positions for 1.5mL/2.0mL test tubes
- Maximum rotational speed: 14, 000rpm (max. RCF: 20, 800 x g)
- Rotor, lids and adapters are autoclavable (121°C, 20min), the rotor FA-45-30-11 with lid can even be autoclaved for 2hr at 140°C, to destroy prion contamination
- High quality, extremely robust aluminium lid for both rotors
- Aerosol-tight centrifugation possible with the rotor FA-45-30-11
- PCR* strip rotor: max. rotational speed 12, 000rpm (max. RCF: 15, 350 x g)
- Up to 6 x 8 tube strips, 6 x 5 tube strips or 48 x 0.2mL PCR* tubes 5804/5804 R and 5810/5810 R centrifuges designed for practically all refrigerated and non-refrigerated applications.
Specifications
4 x 750 mL | |
200 to 14,000 rpm | |
<70 dB(A) | |
2°C to 40°C | |
535 mm | |
608 mm | |
230 V 50/60 Hz |
20,913 x g | |
5810 | |
1 to 99 min. | |
Centrifuge | |
345 mm | |
68 kg | |
900 w |