Filtered Search Results
Thermo Scientific™ TraceGOLD TG-5SilMS GC Columns
Incorporates phenyl groups in the polymer backbone for improved thermal stability, reduced bleed and reduced susceptibility to oxidation.
| Max. Temperature | 330/350°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-5 SilMS |
| Polarity | Low-Polar |
| For Use With (Application) | GC/MS Applications Using Ion-Trap Systems,GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates,GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons |
| USP Type | G27, G36 |
Thermo Scientific™ TraceGOLD TG-5HT GC Columns
Thermo Scientific™ TraceGOLD TG-5HT GC Columns offer extended operation up to 400°C, ideal for high temperature GC applications.
| Max. Temperature | 380/400°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-5 HT |
| Polarity | Low-Polar |
| For Use With (Application) | Pesticides Analysis,GC/MS for Pesticides,GC/MS for Residual Solvents, Solvents, and Solvent Impurities |
| USP Type | G27, G36 |
| Product Line | TraceGOLD |
Thermo Scientific™ TraceGOLD™ TG-624 and TG-624SilMS GC Columns
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
| Polarity | Mid-Polar |
|---|---|
| USP Type | G43 |
Thermo Scientific™ TRACE™ TR-5MS GC Columns
Choose these colums that feature a popular GCMS phase for many applications.
| Stationary Phase | Trace™ TR-5 MS |
|---|---|
| Polarity | Non-Polar |
| USP Type | G27, G36 |
Thermo Scientific™ TraceGOLD™ TG-5MS GC Columns
Employ the most widely used MS phase in gas chromatography with the 5% phenyl phase Thermo Scientific™ TraceGOLD™ TG-5MS GC Column.
| USP Type | G27, G36 |
|---|
Thermo Scientific™ TRACE™ TR-5 GC Columns
Choose these excellent starting columns for method development, capable of performing most required separations.
| Stationary Phase | Trace™ TR-5 |
|---|---|
| Polarity | Non-Polar |
| USP Type | G27, G36 |
Thermo Scientific™ TRACE™ TR-FAME GC Columns
For separation of cis/trans isomers and FAMEs with various degrees of unsaturation, choose this low-bleed, high-polarity column optimized for FAME analysis.
| Max. Temperature | 250/260°C |
|---|---|
| Stationary Phase | Trace™ TR-FAME |
| Polarity | Polar |
| Product Line | TRACE |
Thermo Scientific™ TraceGOLD™ TG-PBDE GC Columns
Use TraceGOLD TG-PBDE GC Columns for fast analysis of polybrominated diphenyl ethers (PBDEs) with high BDE-209 response.
Thermo Scientific™ TraceGOLD™ TG-624SilMS GC Columns, 1.4μm film thickness, 0.25mm I.D., 30m length
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Thermo Scientific™ TraceGOLD TG-1301MS GC Columns
Provides low-bleed, excellent reproducibility and column-to-column consistency even with sensitive detectors like ECDs and MS.
| Max. Temperature | 260/280°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-1301 MS |
| Polarity | Mid-Polar |
| USP Type | G43 |
Thermo Scientific™ TRACE™ GC Columns for Pesticides
Identify organophosphate and organochlorine pesticides with high performance, sensitivity and reproducibility.
| Max. Temperature | 280/300°C |
|---|---|
| Length (Metric) | 30 m |
| Diameter (Metric) | 0.25 mm |
| Diameter (Metric) Inner | 0.25 mm |
| For Use With (Application) | Pesticides Analysis |
| Film Thickness | 0.25 μm |
| USP Type | G43 |
| Product Line | TRACE |
Thermo Scientific™ TRACE™ GC Columns for Dioxin and PCB Analysis
Analyze dioxins and PCBs with high-resolution GC/MS for unsurpassed performance and reproducibility.
| Max. Temperature | 360/370°C |
|---|---|
| Diameter (Metric) | 0.25 mm |
| Diameter (Metric) Inner | 0.25 mm |
| For Use With (Application) | Furan (PCDF) Analysis,GC/MS for Furan (PCDF) Analysis,GC/MS for PCB Congener Analysis |
| USP Type | G27, G36 |
| Product Line | TRACE |
Thermo Scientific™ TraceGOLD™ TG-OCP I and II GC Columns
Analyze organochlorine pesticides and herbicides with ultra low bleed, superior sensitivity, excellent peak shape and the highest levels of reproducibility.
| Max. Temperature | 340°C |
|---|---|
| Polarity | Non-Polar |
Thermo Scientific™ TRACE™ TR-1 GC Columns
Use this non-polar GC column for method development and analysis of chlorinated and nitroaromatic compounds and environmental samples.
| Stationary Phase | TR-1 |
|---|
Thermo Scientific™ TraceGOLD TG-17MS GC Columns
Use these columns for GCMS applications that require more polarity than a 5% phenyl column.
| Max. Temperature | 300/320°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-17 MS |
| Polarity | Mid-Polar |
| USP Type | G43 |